{"id":46500,"date":"2021-07-14T11:24:21","date_gmt":"2021-07-14T08:25:51","guid":{"rendered":"http:\/\/test.koda.ua\/?post_type=product&#038;p=46500"},"modified":"2021-11-29T14:53:54","modified_gmt":"2021-11-29T12:53:54","slug":"rgs40-g","status":"publish","type":"product","link":"https:\/\/test.koda.ua\/en\/product\/rgs40-g\/","title":{"rendered":"Optical incremental linear encoder RGH40"},"content":{"rendered":"<p>When working with the open, non-contact reading head of the\u00a0<b>RGH40 encoder <\/b>using\u00a0RGS40-G glass ruler with a step of 40 \u03bcm by Renishaw is used, with a resolution of up to 50 nm!<\/p>\n<p><b>Features and benefits of the RGH40 reading head<\/b><\/p>\n<p>A compact and robust reading head with an integrated interpolator provides digital and analog output signals that meet the industry standard.<br \/>\n&#8211; High speed and reliability of work with zero friction and no mechanical wear.<br \/>\n&#8211; Scale with a step of 40 microns allows you to work with wide tolerances when installing the reading head.<br \/>\n&#8211; Simple installation and setup procedure due to the presence of a special built-in LED indicator.<\/p>\n<p>The patented optical signal filtering system guarantees high signal stability under conditions that do not allow the use of most open optical encoders.<br \/>\n&#8211; The zero mark ensures the repeatability of the initial position, and the limit switches &#8211; the automatic signal giving the initiating stop of the moved node.<\/p>\n<p>The RGH40 system allows reading from the RGS40-G glass ruler in 40 \u03bcm steps, as well as with the standard 40 \u03bcm glass ruler in the industry.<\/p>\n<p><b>Glass ruler RGS40-G with a step of 40 microns<\/b><\/p>\n<p>Reading from the glass ruler RGS40-G in 40 \u03bcm increments is done with the RGH40 head. The RGS40-G is ideal for situations where it is necessary to move the ruler separately from the substrate. Temperature compensation for the parameters of the RGS40-G is performed by the host controller using temperature sensors.<br \/>\n-We offer rulers with lengths from 120 mm to 1 m.<br \/>\n&#8211; Coefficient of thermal expansion \u2248 8.5 \u03bcm\/m\/<sup>\u00b0<\/sup>\u00a0C.<br \/>\n&#8211; Accuracy &lt;\u00b1 5 \u03bcm\/m.<br \/>\n&#8211; Easily installed directly on the substrate, using the base bracket and mechanical clamps or self-adhesive base.<\/p>\n<p><b>Specifications<\/b><\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"1\" cellpadding=\"4\">\n<tbody>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Built-in LED<br \/>\nhead position indicator<\/td>\n<td class=\"td2 \">Yes<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Measuring range, m:<\/td>\n<td class=\"td1 \">\u2014 optical scale RGS40\u2013G \u2014 up to 1<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Length, m:<\/td>\n<td class=\"td2 \">\u2014 optical scale RGS40\u2013G \u2014 from 0,13 to 1,01<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Resolution of the digital output signal RS422, nm:<\/td>\n<td class=\"td1 \">50, 100, 200, 400, 1000, 2000, 5000, 10 000<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Resolution of the analog output signal:<\/td>\n<td class=\"td2 \">\u2014 1 Vpp<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Step of the scale, mkm:<\/td>\n<td class=\"td1 \">\u2014 optical scale RGS40\u2013G \u2014 40<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Max speed, m\/s:<\/td>\n<td class=\"td2 \">\u2014 for digital output signal \u2014 up to 10<br \/>\n\u2014 for analog output signal \u2014 up to 6<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Clearance between reading head<br \/>\nand optical scale, mm:<\/td>\n<td class=\"td1 \">0,8 \u00b1 0,15<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">System accuracy at 20 \u00b0 C, \u03bcm\/m:<\/td>\n<td class=\"td2 \">\u2014 optical scale RGS40\u2013G \u2014 from \u00b1 0,7 to \u00b1 4,2 (depends on the length of the scale)<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Scale option:<\/td>\n<td class=\"td1 \">\u2014 optical scale RGS40\u2013G \u2014 with base bracket and mechanical clamps or with self-adhesive base<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Coefficient of thermal expansion, \u03bcm\/m\/\u00b0\u0421:<\/td>\n<td class=\"td2 \">\u2014 optical scale RGS40\u2013G \u2014 \u2248 8,5, ends of the scale are fastened by clamps<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Supply voltage, V:<\/td>\n<td class=\"td1 \">5 \u00b1 5 %<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Current consumption (without load), mA:<\/td>\n<td class=\"td2 \">\u2014 120 (in typical conditions)<br \/>\n\u2014 175 (for versions RGH40N, W, Y, H)<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Material:<\/td>\n<td class=\"td1 \">\u2014 optical scale RGS40\u2013G \u2014 glass ruler with chrome strokes<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Cable:<\/td>\n<td class=\"td2 \">\u2014 flexible, 12-core with double shielding, outer diameter 4.7 mm, bending life more than 20 x 10\u00a0<sup>6<\/sup>\u00a0cycles with a bend radius of 50 mm<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Length of the cable, m:<\/td>\n<td class=\"td1 \">0.5, 1, 1.5, 3, 5 (connector type D (15-pin), round connector (12-pin), in-line connector (16-pin) or free terminal (without connector))<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Dimensions of the reading head RGH40 (height \u00d7 length \u00d7 width), mm:<\/td>\n<td class=\"td2 \">17,0 \u00d7 44,0 \u00d7 27,0<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Mass of the reading head, g:<\/td>\n<td class=\"td1 \">50<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Mass of the cable, g\/m:<\/td>\n<td class=\"td2 \">38<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Reference mark (zero):<\/td>\n<td class=\"td1 \">Magnetic actuator (one-way repeatability up to 1 resolution unit)<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Limit switches:<\/td>\n<td class=\"td2 \">\u2013 optical scale RGS40\u2013G \u2013 paired<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Temperature, \u00b0\u0421:<\/td>\n<td class=\"td1 \">\u2014 process \u2014 from 0 to + 55<br \/>\n\u2014 storage \u2014 from \u2013 20 to + 70<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Degree of protection:<\/td>\n<td class=\"td2 \">IP50<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Humidity<br \/>\n(without compensation), %:<\/td>\n<td class=\"td1 \">\u2014 process \u2014 80<br \/>\n\u2014 storage \u2014 95<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Process acceleration, m\/s\u00a0<sup>2<\/sup>:<\/td>\n<td class=\"td2 \">500<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Impact (in non-operating state,<br \/>\n6 ms, half-sinusoidal impulse), m\/s\u00a0<sup>2<\/sup>:<\/td>\n<td class=\"td1 \">1000<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#FFFFFF\">\n<td class=\"tdh centrside\">Vibration (in operation mode, at, at 55-2000 Hz), m\/s\u00a0<sup>2<\/sup>:<\/td>\n<td class=\"td2 \">100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>When working with the open, non-contact reading head of the\u00a0RGH40 encoder using\u00a0RGS40-G glass ruler with a step of 40 \u03bcm by Renishaw is used, with a resolution of up to 50 nm! Features and benefits of the RGH40 reading head A compact and robust reading head with an integrated interpolator provides digital and analog output [&hellip;]<\/p>\n","protected":false},"featured_media":46495,"template":"","meta":[],"product_cat":[2320],"product_tag":[],"producers":[2203],"_links":{"self":[{"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/product\/46500"}],"collection":[{"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/product\/46500\/revisions"}],"predecessor-version":[{"id":46720,"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/product\/46500\/revisions\/46720"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/media\/46495"}],"wp:attachment":[{"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/media?parent=46500"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/product_cat?post=46500"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/product_tag?post=46500"},{"taxonomy":"producers","embeddable":true,"href":"https:\/\/test.koda.ua\/en\/wp-json\/wp\/v2\/producers?post=46500"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}