Series RF600 – sensors with a large range

Producer:

RF600 – triangulation sensors with a working range from 10 to 2500 mm.
Benefits:

  • range up to 2.5 measures in a compact package;
  • various remote distances, depending on the task;
  • available with a blue laser diode, for measuring hot objects.

How it works

Principle of optical triangulation is based on the sensor. The radiation from the semiconductor laser 1 is focused by the objective 2 on the object 6. The objective 3 scattered on the object is collected on the CCD ruler 4. Signal processor 5 calculates the distance to the object from the position of the image of the light spot on the ruler 4.
Application
Triangulation laser sensors are used for high-precision non-contact measurement:

  • thickness / width;
  • size of the object;
  • beats;
  • profile of the object;
  • object movement;
  • sorting the objects.

Specifications

Model RF600- X/10 X/10 X/40 X/100 X/250 X/500 X/600 X/1000 X/1000 X/1500 X/2000 X/2500
Base distance X, mm: 230 300 330 500 230 300, 1000 230 1300 380 390 410 420
Range, mm: 10 30 40 100 250 500 600 1000 1000 1500 2000 2500
Linearity, %: ± 0,1 from range to range ± 0,2
Resolution, %: 0,01 from the range (only for digital output) 0,03
Temperature drift, °С: 0,02% from the range
Maximum data update rate, kHz: 9,4
Source of radiation: visible red semiconductor laser, wavelength 660 nm, or
ultraviolet semiconductor laser, wavelength 405 nm (version with BLUE laser)
Radiation power, mW: ≤ 4,8 ≤ 20
Safety class: 3R (IEC60825-1) 3В (IEC60825-1)
Output interface:
  • digital
  • RS232 (max 460,8 Kbps) or RS485 (max 921,6 Kbps) or
    RS232 and CAN V2.0B (max 1 Mbps) or Ethernet and (RS32 or RS485)
  • analog
  • 4 … 20 mA (load ≤ 500 Om) or 0 … 10 V
    Sync input: 2,4 – 5 V (CMOS, TTL)
    Logical output: programmable functions, NPN: 100 mA max; 40 V max
    Supply voltage, V: 9 … 36
    Power consumption, W: 1,5 … 2
    Resistance to external influences:
  • protection class
  • IP67 (only for sensors with a connector on the housing)
  • level of vibration
  • 20 g /10 … 1000 Hz, 6 hours for each XYZ axes
  • impact loads
  • 30 g / 6 ms
  • ambient temperature, °С:
  • -10 … +60
  • ambient light, lux
  • 30000
  • relative humidity
  • 5 – 95% (without condensation)
  • Storage temperature, °С:
  • -10 … +60, (-30 … +60 for sensors with integrated heater)
    Material of the housing: aluminum
    Mass (without cable), gram: 500

    Note: All values are for a white matte surface, for other types of surfaces, the values may differ.

    No downloads for this product.