Series RF603 – universal laser sensors

Producer:

RF603 – Universal sensors with a working range from 2 to 1250 mm.
Available:

  • with red and blue laser diode;
  • lasers of different power;
  • binocular sensors for laser scanning.

How it works

The principle of optical triangulation is based on the sensor. The radiation from the semiconductor laser 1 is focused by the objective 2 on the object 6. The objective 3 scattered by the object is collected on the CCD ruler 4. The signal processor 5 calculates the distance to the object from the position of the image of the light spot on the ruler 4.
Application
Triangulation laser sensors are used for high-precision non-contact measurement:

  • thickness / width;
  • size of the object;
  • beats;
  • profile of the object;
  • object movement;
  • sorting objects.

Specifications

Model RF603- R-X/4 X/2 X/5 X/10 X/15 X/25 X/30 X/50 X/100 X/250 X/500 X/750 X/1000 X/1250
Base distance X, mm: 39 15 15 15, 25, 60 15, 30, 65 25, 45, 80 35, 55, 95 45, 65, 105 60, 90, 140 80 125 145 245 260
Range, mm: 4 2 5 10 15 25 30 50 100 250 500 750 1000 1250
Linearity, %: ± 0,05 from range ± 0,1
Resolution, %: 0,01 range (just for digital output) 0,02
Temperature drift, °С: 0,02% of the range
Maximum data update rate, kHz: 2 or 9,4
Source of radiation: visible red semiconductor laser, wavelength 660 nm visible ultraviolet semiconductor laser, wavelength 405 nm (version BLUE)
Source of radiation:
  • variant of execution
  • RF603
  • power of radiation
  • ≤0,2 ≤3 mW ≤5 mW
  • safety class
  • 1 3R (IEC60825-1)
  • variant of execution
  • RF603L
  • power of radiation
  • ≤ 0,95 mW
  • safety class
  • 2 (IEC60825-1)
  • variant of execution
  • RF603Р
  • power of radiation
  • ≤20 mW
  • safety class
  • 3В (IEC60825-1)
    Output interface:
  • digital
  • RS232 (max 460,8 Kbps) or RS485 (max 921,6 Kbps) or RS232 and CAN V2.0B (max 1 Mbps) or Ethernet and (RS32 or RS485)
  • analog
  • 4 … 20 mA (load ≤ 500 Om) or 0…10 В
    Sync input: 2,4 – 5 В (CMOS, TTL)
    Logical output: programmable functions, NPN: 100 мА max; 40 V max
    Supply voltage, V: 9 … 36
    Power consumption, W: 1,5 … 2
    Resistance to external influences:
  • protection class
  • IP67 (only for sensors with a connector on the housing)
  • level of vibration
  • 20 g /10 … 1000Hz, 6 hours for each of XYZ axes
  • impact loads
  • 30 g / 6 ms
  • ambient temperature, °С
  • -10 … +60 (-30 … +60 for sensors with integrated heater), (-30 … +120 for sensors with integrated heater and protective housing)
  • ambient light, lux
  • 10000 – RF603L, 30000 – RF 603, >30000 – RF 603P
  • relative humidity
  • 5 – 95% (without condensation)
  • Storagetemperature, °С
  • -20 … +70
    Material of the housing: aluminum
    Mass (without cable), gram: 100

    Note 1: All values are for a white matte surface, for other types of surfaces, the values may differ.
    Note 2: RF603-R-39/4 sensor is designed to control mirror objects and glass.